Publications

Publications

Articles(2026) Enhanced Visualization: Transforming Non-Contrast into Contrast-Enhanced Computed Tomography Images Through Advanced Generative Adversarial Networks


저널/학회명

Diagnostics


게재연도

2026


초록


• Background/Objectives

Contrast-enhanced CT (CECT) is essential for mediastinal and lymph node assessment but is often limited in patients with renal dysfunction, prior severe contrast reactions, or pediatric populations. Deep learning approaches, such as generative adversarial networks (GANs), allow the generation of synthetic CECT (sCECT) from non-contrast CT (NCCT) without contrast injection.


• Materials and Methods

A GAN-based model was trained using 400 CECT scans acquired between March and July 2024. The model was tested in 20 patients with lymphoma or metastatic lymphadenopathy diagnosed between January and July 2025, using only NCCT scans. Quantitative evaluation compared sCECT with CECT using Mean Absolute Error (MAE), Root Mean Square Error (RMSE), Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index (SSIM), and Pearson Correlation Coefficient (PCC). Two radiologists performed qualitative assessment, and Signal-to-Noise Ratio (SNR)/Contrast-to-Noise Ratio (CNR) values were measured for thoracic structures.


• Results

Compared with NCCT, sCECT demonstrated slightly lower MAE (20.87 ± 8.84 vs. 21.26 ± 9.26) and RMSE (45.22 ± 14.22 vs. 45.94 ± 15.07), and marginally higher PSNR (15.44 ± 2.70 vs. 15.38 ± 3.02), indicating modest improvements in pixel-wise similarity. SSIM values were comparable (0.610 ± 0.09 vs. 0.63 ± 0.10), while PCC decreased (0.61 ± 0.09 vs. 0.77 ± 0.15). All differences were statistically significant (p < 0.001). Despite these mixed quantitative results, sCECT was qualitatively rated significantly higher by radiologists, with improved visualization of mediastinal structures. SNR and CNR analyses further supported enhanced contrast depiction in sCECT compared with NCCT.


• Conclusions

The GAN-based model successfully generated sCECT from NCCT with modest quantitative similarity gains but clear qualitative improvement, particularly for mediastinal lymph node evaluation. Although synthetic enhancement represents a learned intensity transformation rather than true iodine-based attenuation, sCECT may serve as a valuable adjunct in patients with contraindications to iodinated contrast.



DOI

https://doi.org/10.3390/diagnostics16060861

폴스타헬스케어와 함께
디지털 헬스케어의

새로운 기준을 만나보세요.

폴스타헬스케어 주식회사


Address
서울특별시 서초구 강남대로 331, 광일프라자 20층
CEO
윤여동
Call
+82) 02-521-4621
Fax
+82) 02-521-4821

Sitemap


©2026 Polestar Healthcare. All Rights Reserved


폴스타헬스케어 주식회사

Address 서울특별시 서초구 강남대로 331,
광일프라자 20층
CEO 윤여동
Call+82) 02-521-4621
Fax+82) 02-521-4821

©2026 Polestar Healthcare. All Rights Reserved